Quality Management Systems universally ask for calibration of all the measuring equipment that can affect the quality of the final product. While calibration of gauging equipment is typically understood, the significance of calibrating temperature sensors is ignored sometimes.

Undeniably, even a slight change in the required temperature can influence the quality of the product and the trade of its safety. So, thermal calibration is vital for quality assurance. Thermal maintenance is additionally crucial in cold chains and nuclear sites. This is the reason one of the fundamental areas you have to consider is calibration of thermal equipment.

We have facility to calibrate various sensor/ temperature controller cum indicator in range of (-) 80 to 1200 deg C

Calibration Thermal
Our Thermal Calibration Scope
Instrument Range
RTD/ Thermocoule sensor with or without Indicator (-) 80 °C to 1200 °C
Temperature Transmitter with or without indicator (-) 80 °C to 300°C
Temperature Switch 0 °C to 300°C
Temperature Chart Recorder (-) 80 °C to 1200 °C
Glass/ Digital Thermometers & Temperature Gauge (-) 80 °C to 300 °C
Deep freezer/ Refrigarator/ Cold Chambers (-) 80 to Amb °C
BOD Incubator Amb to 600 °C
Water Bath Amb to 100 °C
HPLC,/GC-MS Temperature Ovens / Shaker Bath/ Liquid Bath Amb to 600 °C
Muffle furnace OR Temperature Ovens/ Dry Block Calibrator/ Heating Mentle or Block Amb to 1200°C
Thermo Hygrometer (Table Top )/ Relative Humidity Probe or Tansmitter with sensor 10 % Rh to 95 % RH @ 25 °C & 10 °C to 50 °C @ 50 % RH
Data Logger (Per Channel) 10 % Rh to 95 % RH @ 25 °C & 10°C to 50 °C @ 50 % RH
Humidity Calibrator/Generator & Environmental Chamber (Single Ponit Sensor calibration) 10 % RH to 95 % RH
IR Thermometer/ Thermal Imagers/ Pyrometers 50°C to 1200°C
Validation of Autoclave (Temperature / Pressure Mapping ) 9/ 16 sensor method for various temp/ humidity points
Validation of Stability Chamber/ walking Chamber/ Environmental chamber -- Mapping 9/ 16 sensor method for various temp/ humidity points
Validation of Deep freezer/ Refrigerator/ Cold Chamber/ BOD Incubator/ Oven/ Muffle Furnace 9/ 16 sensor method for various temp/ humidity points
Area Mapping (Temperature & Relative Humidity) As per customer protocol - Data loggers Used.